Construction conditions
The substrate temperature must be 3 ℃ above the dew point
Relative humidity not exceeding 85%
Suitable for use as anti rust primer on aluminum alloys, galvanized steel, and steel surfaces.
Construction parameters
|
product name
|
F53-34(725)
|
F53-34(725-1)
|
F53-34(725-2)
|
|
Density about g/cm3
|
1.36
|
1.45
|
1.5
|
|
Dry film thicknessμm
|
40
|
40
|
40
|
|
Wet Film Thicknessμm
|
75
|
89
|
89
|
|
Theoretical coating amount m2/kg
|
9.3
|
7.8
|
7.5
|
Suggested number of coating layers
Second layer, dry film thickness of 80 μ m
Rear supporting paint